What Size Extractor Fan Do I Need? UK Home & Industrial Ventilation Guide

What Size Extractor Fan Do I Need? UK Home & Industrial Ventilation Guide

Choosing an extractor fan starts with the air you need to move and the place it will be installed. Diameter alone cannot tell you whether a fan will ventilate a bathroom, clear warm air from a workshop or work through a long duct. Two fans with the same nominal size can have different motors, airflow ratings and noise characteristics.

This guide explains room area, volume, air changes per hour and airflow in m³/h. Use the calculator to establish a preliminary airflow target, then compare the relevant Powerstar range. A final choice also needs checks for pressure, electrical installation, moisture, noise and the air being extracted.

Why Choosing the Correct Extractor Fan Size Matters

A fan that delivers too little air can leave moisture, odours or excess heat behind. A larger fan can create unnecessary noise, draughts and running costs if it is poorly matched to the room. Extraction also needs replacement air: a powerful fan cannot deliver its expected flow through a sealed room with no suitable air inlet.

Start by identifying the purpose. Removing bathroom moisture, providing outdoor air for office occupants and capturing welding fumes are different jobs. General room extraction does not replace a designed local exhaust ventilation system for hazardous contaminants. Likewise, a circulating cooling fan can improve comfort without exchanging indoor air with outdoor air.

Extractor Fan Size Calculator – Find Your Required Airflow

Enter the room length, width and ceiling height in metres, or enter a known floor area and height. If you already know the room volume, use that option. Select the application, installation type and a ventilation rate appropriate to the project.

The calculator uses room volume × selected ACH = preliminary airflow in m³/h. It displays published product data where an application and installation match can be established. A result is a shortlist for verification, rather than confirmation that a fan will achieve the target once installed.

For domestic bathrooms and kitchens, the England intermittent extract figures described below are shown separately. Continuous systems, whole dwelling ventilation and projects elsewhere in the UK need their own checks. Duct length and bends trigger a pressure verification message; the calculator does not apply a guessed percentage loss.

Use the interactive calculator below to calculate your preliminary airflow target.

How to Calculate Room Volume in Cubic Metres

First calculate floor area: length × width = area in m². Multiply the area by the average internal ceiling height to obtain volume in m³. Measure the space actually being ventilated. For irregular rooms, divide the plan into rectangles and add the volumes. Use a measured average height for sloping ceilings.

A workshop measuring 10 metres by 8 metres has an area of 80m². With a 3 metre ceiling, its volume is 240m³. At an illustrative 6 ACH, the calculation is 240 × 6 = 1,440m³/h. Six ACH in this example is a chosen assumption, not a universal workshop requirement.

If you enter volume alone, floor area cannot be calculated without height. The calculator therefore requests height as well when an area result is wanted. Avoid entering external building dimensions, which can overstate the usable internal volume.

What Does m³/h Mean on an Extractor Fan?

Cubic metres per hour describes volume flow. A rating of 1,000m³/h means a stated volume of air moved per hour under the rating conditions. Always ask what those conditions were: a free-air or maximum figure does not establish performance against your duct system's resistance.

Some UK ventilation guidance uses litres per second. Multiply l/s by 3.6 to convert to m³/h, or divide m³/h by 3.6 to obtain l/s. For example, 15l/s equals 54m³/h and 60l/s equals 216m³/h. Keep units consistent when comparing a design requirement with a product table.

Understanding Air Changes Per Hour (ACH)

ACH expresses the hourly ventilation volume relative to the room volume. In a 100m³ room, 600m³/h corresponds to 6 ACH. It does not mean every pocket of air is completely replaced six times: mixing, supply positions, obstructions and short circuits affect real ventilation.

There is no single authoritative UK ACH value covering every garage, warehouse or industrial process. Occupancy, moisture, heat and contaminants change the design requirement. The calculator leaves commercial ACH for the user or designer to select rather than label an arbitrary preset as a legal standard.

HSE describes general workplace fresh-air provision using flow per person, with its guidance referring to 5–8l/s per occupant and noting that some building guides use 10l/s per person. This is outdoor air provision and does not establish the extraction rate for a hazardous process. An office's ACH calculation should be checked against occupancy and the applicable non-domestic requirements. [2]

Recommended Ventilation for Different Applications

England domestic guidance: Approved Document F Volume 1, 2021 edition, Table 1.1 gives these minimum intermittent extract rates: bathroom 15l/s (54m³/h); utility room 30l/s (108m³/h); sanitary accommodation 6l/s (21.6m³/h); kitchen with an externally exhausting cooker hood 30l/s (108m³/h); kitchen without that arrangement 60l/s (216m³/h). These figures describe particular systems and do not replace the other provisions of the document. [1]

Continuous extract has different room high rates and whole dwelling requirements. Do not use the intermittent bathroom figure as the design for a continuous whole house system. A recirculating cooker hood also does not discharge air outdoors.

As checked on 3 November 2026, England's published 2026 Volume 1 takes effect on 24 March 2027 for work outside the higher-risk category and on 24 September 2027 for higher-risk work, subject to transitional arrangements. Check the edition applicable to the actual project. Approved Document F is England guidance; Wales, Scotland and Northern Ireland have their own documents. [5–8]

For garages, workshops and warehouses, specify the activity before choosing ACH. Offices and restaurant dining areas need occupancy-based outdoor air checks. Commercial kitchens need canopy capture, replacement air and appropriate discharge design. Industrial premises handling dust, solvents, fumes or explosive atmospheres need a competent assessment and equipment selected for those conditions. [2–4]

Best Extractor Fans for Bathrooms and Domestic Spaces

Begin with products intended for domestic ventilation. Confirm the exact model's airflow, mounting method, moisture protection, permitted installation position and control arrangement. A product being listed in a bathroom category does not confirm suitability for every bathroom electrical zone.

Consider a small bathroom measuring 2m × 2m × 2.4m. Its area is 4m² and its volume is 9.6m³. An illustrative 6 ACH gives 57.6m³/h, just above the England intermittent bathroom benchmark of 54m³/h. The installed fan must still deliver the design flow through the actual grille and duct, and the installer must verify electrical suitability.

For a domestic kitchen, distinguish a cooker hood exhausting outdoors from general extraction. Do not substitute an industrial wall fan solely because its airflow exceeds a kitchen figure. Grease handling, cleaning access, noise and electrical suitability all matter. If the catalogue lacks a necessary rating, request the model's data sheet before purchase.

Choosing an Industrial Extractor Fan for a Workshop

Record the workshop dimensions, number of occupants, heat sources and activities. For general warm-air extraction, a wall-mounted axial fan may be a candidate where the discharge is short and the pressure requirement is low. For ducted arrangements, request performance at the required pressure.

For the 240m³ workshop example at a designer-selected 6 ACH, the preliminary target is 1,440m³/h. Compare individual size rows in the Powerstar table, then check the discharge, make-up air and sound data. A speed controller is useful only where the motor and controller are confirmed compatible; a reduced speed changes performance.

For a garage measuring 6m × 4m × 2.5m, the volume is 60m³. A chosen 4 ACH gives 240m³/h. This arithmetic does not size vehicle exhaust extraction and does not authorise running an engine indoors. Welding, spraying, machining and dusty processes require separate assessment and may require source capture. [3]

What Size Extractor Fan Does a Warehouse Need?

Large volume does not tell the whole story. Include working zones, roof height, stored materials, vehicle activity, occupancy and heat gains. Air entering beside the extraction point can leave remote areas poorly ventilated. A designer may need several supply and extract locations rather than one large fan.

A 30m × 20m premises with a 6m ceiling has a volume of 3,600m³. At an illustrative 3 ACH, the target is 10,800m³/h. This is an example calculation, not a recommended warehouse rate. Do not add several free-air fan ratings together and assume the installed system achieves that total.

Confirm whether the project needs general fresh-air ventilation, heat removal or contaminant control. A portable industrial cooling fan may help workers feel cooler, but air circulation within the building is not an equivalent outdoor-air exchange rate.

Extractor Fan Noise Levels Explained – Understanding dB(A)

The A-weighted decibel scale describes sound with a weighting related to human hearing. Compare like-for-like measurements: sound power and sound pressure are different quantities, and sound pressure depends on distance and surroundings. A value without the measurement method or distance is not a reliable promise about how a room will sound.

Do not treat a published value marked only “dB” as verified dB(A). The comparison retains the website's unit and flags an unspecified weighting. Missing sound data remains unpublished. The calculator's Quiet option requires a stated dB(A) rating and shows the user's chosen ceiling; it cannot certify bedroom or boundary noise compliance.

Vibration isolation, duct treatment, fan speed and mounting stiffness can affect perceived noise. Ask for comparable sound data and consider where neighbours, staff and occupants will be in relation to the fan and discharge.

Wall-Mounted vs Portable vs Ducted Extractor Fans

Wall-mounted fans suit fixed openings where the structure, weather protection and discharge arrangement are appropriate. Ceiling fans need confirmation of the permitted orientation, support and discharge route. Keep maintenance and cleaning access in the design.

Portable ventilation fans offer flexibility for temporary clean-air movement. Their useful flow still depends on connected hose and the inlet and outlet arrangement. A normal portable blower is not automatically suitable for confined-space entry or hazardous air. Specialist procedures and equipment may be necessary.

Ducted fans allow remote extraction and discharge positions. Select them by airflow at pressure, duct compatibility and environmental rating. Accessories such as shutters and mesh grilles add resistance. Product links should help identify the right category while the installer confirms the full arrangement.

How Ducting and Static Pressure Affect Airflow

Air loses pressure as it passes through ducts, bends, filters, shutters and grilles. Flexible hose can create considerable resistance if compressed or sharply bent. A longer route with several fittings may need a different fan type from a short straight wall discharge.

Final selection uses the required flow at the calculated system pressure: the fan curve and system resistance determine the operating point. A maximum pressure value and a maximum airflow value are usually different points; they should not be assumed to occur together. [3]

Duct length and bend count alone cannot establish the pressure loss. Diameter, air velocity, bend geometry, roughness, filter loading and terminals also matter. The calculator therefore flags these inputs for design review and does not invent an “add 20%” rule. Ask for a curve or verified duty-point data, and commission the installed airflow.

Powerstar Extractor Fan Size and Specification Comparison

The comparison below separates the published sizes and retains the exact product family title. Airflow, watts, voltage and sound values are included only where a readable specification assigns them to a model. Unpublished or conflicting information is identified rather than filled from a similarly sized fan.

Nominal inch and millimetre sizes are shown as advertised where both are stated. These rounded trade sizes are not an instruction for cutting a wall opening or ordering a connector. Confirm the manufacturer's dimensional drawing and the actual duct connection.

Power in watts describes electrical input where the listing identifies it as such; it is not a substitute for airflow performance. For a simple energy estimate, a 100W fan running for five hours uses 0.5kWh at that constant input. Multiply by your electricity unit rate to estimate the energy cost.

Open full fan specification comparison (186 size rows)

*A published pressure and airflow are not verified as a paired operating point. dB is not assumed to mean dB(A). Cooling fans are identified as circulation products and excluded from extraction matching. Blank values are unpublished, never zero.

Model / product codeDiameterPublished m³/hNoisePower WSupplyPressure Pa*Installation / applicationChecks / missing data
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003201 · variation
200mm / 8in1800.062.0 dB (weighting not stated)80.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003202 · variation
250mm / 10in2520.064.0 dB (weighting not stated)110.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003203 · variation
300mm / 12in3480.068.0 dB (weighting not stated)133.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003204 · variation
350mm / 14in4620.070.0 dB (weighting not stated)240.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003239 · variation
400mm / 16in4800.072.0 dB (weighting not stated)155.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003240 · variation
450mm / 18in6480.073.0 dB (weighting not stated)220.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003241 · variation
500mm / 20in7500.076.0 dB (weighting not stated)275.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL1003242 · variation
550mm / 22in7800.082.0 dB (weighting not stated)364.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan – Heavy-Duty Axial Ventilation Exhaust Fan, 200–600mm
EL10033458 · variation
600mm / 24in9480.082.0 dB (weighting not stated)470.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL1003201- · variation
200mm / 8in1800.062.0 dB (weighting not stated)80.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL1003202- · variation
250mm / 10in2520.064.0 dB (weighting not stated)110.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL1003203- · variation
300mm / 12in3480.068.0 dB (weighting not stated)133.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL1003359 · variation
350mm / 14in4620.070.0 dB (weighting not stated)240.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL1003239- · variation
400mm / 16in4800.072.0 dB (weighting not stated)155.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL1003360- · variation
450mm / 18in6480.073.0 dB (weighting not stated)220.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL10033590- · variation
500mm / 20in7500.076.0 dB (weighting not stated)275.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL10033588- · variation
550mm / 22in7800.082.0 dB (weighting not stated)364.0220–240VUnpublishedWall · industrial 
Heavy Duty Industrial Extractor Fan with Speed Controller – 8" to 24" (200–600mm)
EL10033589- · variation
600mm / 24in9480.082.0 dB (weighting not stated)470.0220–240VUnpublishedWall · industrial 
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033813 · variation
200mm / 8in780.056.0 dB (weighting not stated)65.0220–240V120.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033638 · variation
200mm / 8in780.056.0 dB (weighting not stated)65.0220–240V120.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033639 · variation
250mm / 10in1850.065.0 dB (weighting not stated)140.0220–240V190.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
SKU unpublished · Variation SKU unpublished; not inherited from another option
250mm / 10in1850.065.0 dB (weighting not stated)140.0220–240V190.0Wall / Ducted · industrialvariation SKU unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033640 · variation
300mm / 12in2530.069.0 dB (weighting not stated)180.0220–240V120.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033567 · variation
300mm / 12in2530.069.0 dB (weighting not stated)180.0220–240V120.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033568 · variation
350mm / 14in2450.065.0 dB (weighting not stated)150.0220–240V90.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033554 · variation
350mm / 14in2450.065.0 dB (weighting not stated)150.0220–240V90.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033641 · variation
400mm / 16in3950.069.0 dB (weighting not stated)180.0220–240V100.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033569 · variation
400mm / 16in3950.069.0 dB (weighting not stated)180.0220–240V100.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033570 · variation
450mm / 18in5350.068.0 dB (weighting not stated)280.0220–240V100.0Wall / Ducted · industrialNo stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033636 · variation
500mm / 20in7250.070.0 dB (weighting not stated)450.0220–240V125.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033571 · variation
500mm / 20in7250.070.0 dB (weighting not stated)450.0220–240V125.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033637 · variation
600mm / 24in9500.075.0 dB (weighting not stated)750.0220–240V230.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Speed Controller – Wall Mounted Axial Fan 8–24 Inch
EL10033672 · variation
600mm / 24in9500.075.0 dB (weighting not stated)750.0220–240V230.0Wall / Ducted · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Industrial Extractor Fan with Metal Louvre Shutter – Heavy Duty Wall Mounted Ventilation Fan 12"–24"
EL1003348 · variation
300mm / 12in1800.0Unpublished80.0220–240V30.0Wall · industrialnoise unpublished;
Industrial Extractor Fan with Metal Louvre Shutter – Heavy Duty Wall Mounted Ventilation Fan 12"–24"
EL1003349 · variation
400mm / 16in3480.0Unpublished150.0220–240V90.0Wall · industrialnoise unpublished;
Industrial Extractor Fan with Metal Louvre Shutter – Heavy Duty Wall Mounted Ventilation Fan 12"–24"
EL10033724 · variation
500mm / 20in6600.0Unpublished350.0220–240V100.0Wall · industrialnoise unpublished;
Industrial Extractor Fan with Metal Louvre Shutter – Heavy Duty Wall Mounted Ventilation Fan 12"–24"
EL10033757 · variation
600mm / 24in7800.0Unpublished450.0220–240V110.0Wall · industrialnoise unpublished;
Industrial Portable Ventilation Fan – Wheeled Axial Blower & Extractor, 16"–24"
EL10033708 · variation
400mm / 16in7200.070.0 dB(A)1200.0UnpublishedUnpublishedPortable · industrialsupply unpublished; Voltage unpublished in readable description; verify supply before purchase.
Industrial Portable Ventilation Fan – Wheeled Axial Blower & Extractor, 16"–24"
EL10033725 · variation
450mm / 18in9600.070.0 dB(A)1800.0UnpublishedUnpublishedPortable · industrialsupply unpublished; Voltage unpublished in readable description; verify supply before purchase.
Industrial Portable Ventilation Fan – Wheeled Axial Blower & Extractor, 16"–24"
EL1003249 · variation
500mm / 20in7800.070.0 dB(A)550.0UnpublishedUnpublishedPortable · industrialsupply unpublished; Voltage unpublished in readable description; verify supply before purchase.
Industrial Portable Ventilation Fan – Wheeled Axial Blower & Extractor, 16"–24"
EL1003250 · variation
600mm / 24in12600.075.0 dB(A)750.0UnpublishedUnpublishedPortable · industrialsupply unpublished; Voltage unpublished in readable description; verify supply before purchase.
Powerful Inline Extractor Duct Fan Ventilation Hydroponics Grow Room Mixed Flow
EL10033709 · variation
100mm / 4in165Unpublished44UnpublishedUnpublishedDucted · domesticnoise unpublished; supply unpublished; Moisture protection and bathroom zone suitability not published; installer verification required.
Powerful Inline Extractor Duct Fan Ventilation Hydroponics Grow Room Mixed Flow
EL10033711 · variation
150mm / 6in405Unpublished60UnpublishedUnpublishedDucted · domesticnoise unpublished; supply unpublished; Moisture protection and bathroom zone suitability not published; installer verification required.
Powerful Inline Extractor Duct Fan Ventilation Hydroponics Grow Room Mixed Flow
EL10033712 · variation
200mm / 8in675Unpublished130UnpublishedUnpublishedDucted · domesticnoise unpublished; supply unpublished; Moisture protection and bathroom zone suitability not published; installer verification required.
New Ceiling Extractor Centrifugal Ventilation Exhaust Fan
EL10033456 · variation
200mm / 8in12042 dB (weighting not stated)32220–240VUnpublishedCeiling · domesticConflicting size labels: descriptive and selected sizes 200/250mm, technical text 150/200mm. 100mm duct connection; advertised fan size is not the duct size. IP and zone suitability need verification.
New Ceiling Extractor Centrifugal Ventilation Exhaust Fan
EL10033457 · variation
250mm / 10in19248 dB (weighting not stated)35220–240VUnpublishedCeiling · domesticConflicting size labels: descriptive and selected sizes 200/250mm, technical text 150/200mm. 100mm duct connection; advertised fan size is not the duct size. IP and zone suitability need verification.
Ceiling Extractor Centrifugal Extractor Ventilation Exhaust Fan Bathroom Kitchen
EL10033446 · variation
200mm / 8in12042 dB (weighting not stated)32220–240VUnpublishedCeiling · domestic100mm duct connection; advertised fan size is not the duct size. IP and zone suitability need verification.
Ceiling Extractor Centrifugal Extractor Ventilation Exhaust Fan Bathroom Kitchen
EL10033447 · variation
250mm / 10in19248 dB (weighting not stated)35220–240VUnpublishedCeiling · domestic100mm duct connection; advertised fan size is not the duct size. IP and zone suitability need verification.
Slimline 100mm 4'' Ventilation Extractor PVC Kitchen Bathroom Wall Ceiling Fan
EL10033445 · displayed product code; variation SKU not verified
100mm / 4inUnpublished38 dB (weighting not stated)15220–240VUnpublishedWall / Ceiling · domesticairflow unpublished; Airflow unpublished; excluded from airflow matching.
Air Intake & Extraction Fan Shutter Pull Cord Kitchen Bathroom Toilet 6", 8" & 12" Inches
EL1003317-a · variation
150mm / 6in21037 dB (weighting not stated)30220–240VUnpublishedWall · domesticIPX2 published; do not assume suitability for bathroom splash zones. Installer confirmation required.
Air Intake & Extraction Fan Shutter Pull Cord Kitchen Bathroom Toilet 6", 8" & 12" Inches
EL1003317-b · variation
200mm / 8in45039 dB (weighting not stated)30220–240VUnpublishedWall · domesticIPX2 published; do not assume suitability for bathroom splash zones. Installer confirmation required. No stock shown in captured variation data.
Air Intake & Extraction Fan Shutter Pull Cord Kitchen Bathroom Toilet 6", 8" & 12" Inches
EL10033541 · variation
300mm / 12in100047 dB (weighting not stated)45220–240VUnpublishedWall · domesticIPX2 published; do not assume suitability for bathroom splash zones. Installer confirmation required. No stock shown in captured variation data.
Metal Industrial Ventilation Extractor Axial Exhaust Fan With Speed Controller
EL10033692 · variation
200mm / 8in78056 dB (weighting not stated)65220–240V120Wall · industrialNo stock shown in captured variation data.
Metal Industrial Ventilation Extractor Axial Exhaust Fan With Speed Controller
EL10033693 · variation
250mm / 10in185065 dB (weighting not stated)140220–240V190Wall · industrial 
Metal Industrial Ventilation Extractor Axial Exhaust Fan With Speed Controller
EL10033694 · variation
300mm / 12in330066 dB (weighting not stated)180220–240V210Wall · industrial 
Metal Industrial Ventilation Extractor Axial Exhaust Fan With Speed Controller
EL10033750 · variation
400mm / 16in648069 dB (weighting not stated)530220–240V150Wall · industrial 
Metal Industrial Ventilation Extractor Axial Exhaust Fan With Speed Controller
EL10033695 · variation
450mm / 18in540069 dB (weighting not stated)320220–240V150Wall · industrial 
Metal Industrial Ventilation Extractor Axial Exhaust Fan With Speed Controller
EL10033696 · variation
500mm / 20in888072 dB (weighting not stated)400220–240V190Wall · industrial 
Metal Industrial Ventilation Extractor Axial Exhaust Fan With Speed Controller
EL10033697 · variation
600mm / 24in1302075 dB (weighting not stated)750220–240V230Wall · industrial 
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033632 · variation
300mm / 12in3300Unpublished180220–240V260Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033698 · variation
300mm / 12in3300Unpublished180220–240V260Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033814 · variation
350mm / 14in4850Unpublished420220–240V285Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033824 · variation
350mm / 14in4850Unpublished420220–240V285Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033633 · variation
400mm / 16in6200Unpublished520220–240V310Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033699 · variation
400mm / 16in6200Unpublished520220–240V310Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033741 · variation
450mm / 18in5410Unpublished280220–240V160Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033825 · variation
450mm / 18in5410Unpublished280220–240V160Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033688 · variation
500mm / 20in850Unpublished370220–240V200Ducted · industrialnoise unpublished; Published 850m³/h looks anomalous against adjacent sizes; retained unchanged and excluded pending confirmation. Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033634 · variation
500mm / 20in850Unpublished370220–240V200Ducted · industrialnoise unpublished; Published 850m³/h looks anomalous against adjacent sizes; retained unchanged and excluded pending confirmation. Size-level performance; package/controller options have separate SKUs. Select the exact option.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033758 · variation
550mm / 22in10800Unpublished550220–240V190Ducted · industrialnoise unpublished; No stock shown in captured variation data.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033667 · variation
600mm / 24in13000Unpublished750220–240V270Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Cased Axial Extractor Fan Canopy Industrial Duct Hose
EL10033700 · variation
600mm / 24in13000Unpublished750220–240V270Ducted · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Heavy Duty Industrial Metal Axial Fume Extractor Ventilation Fan with Louver Shutter
EL10033737 · variation
300mm / 12in1800Unpublished120220–240V45Wall · industrialnoise unpublished; Airflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. No stock shown in captured variation data.
Heavy Duty Industrial Metal Axial Fume Extractor Ventilation Fan with Louver Shutter
EL10033738 · variation
400mm / 16in3480Unpublished180220–240V90Wall · industrialnoise unpublished; Airflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating.
Heavy Duty Industrial Metal Axial Fume Extractor Ventilation Fan with Louver Shutter
EL10033739 · variation
500mm / 20in6000Unpublished370220–240V100Wall · industrialnoise unpublished; Airflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating.
Heavy Duty Industrial Metal Axial Fume Extractor Ventilation Fan with Louver Shutter
EL10033740 · variation
600mm / 24in9000Unpublished550220–240V110Wall · industrialnoise unpublished; Airflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL10033690 · variation
200mm / 8in150061 dB (weighting not stated)180220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003243 · variation
200mm / 8in150061 dB (weighting not stated)180220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
ELG10033702 · variation
200mm / 8in150061 dB (weighting not stated)180220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL10033612 · variation
250mm / 10in270066 dB (weighting not stated)300220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003141 · variation
250mm / 10in270066 dB (weighting not stated)300220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
ELG10033701 · variation
250mm / 10in270066 dB (weighting not stated)300220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL10033613 · variation
300mm / 12in390069 dB (weighting not stated)500220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003142 · variation
300mm / 12in390069 dB (weighting not stated)500220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
ELG10033700 · variation
300mm / 12in390069 dB (weighting not stated)500220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL10033708 · variation
400mm / 16in720070 dB (weighting not stated)1200220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003143 · variation
400mm / 16in720070 dB (weighting not stated)1200220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL10033614 · variation
400mm / 16in720070 dB (weighting not stated)1200220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL10033725 · variation
450mm / 18in660070 dB (weighting not stated)700220–240V350Portable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003144 · variation
450mm / 18in660070 dB (weighting not stated)700220–240V350Portable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
ELG1002364 · variation
450mm / 18in660070 dB (weighting not stated)700220–240V350Portable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003249 · variation
500mm / 20in780070 dB (weighting not stated)550220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003245 · variation
500mm / 20in780070 dB (weighting not stated)550220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
ELG1003253 · variation
500mm / 20in780070 dB (weighting not stated)550220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003250 · variation
600mm / 24in1260075 dB (weighting not stated)750220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
EL1003246 · variation
600mm / 24in1260075 dB (weighting not stated)750220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan
ELG1003254 · variation
600mm / 24in1260075 dB (weighting not stated)750220–240VUnpublishedPortable · industrialSize-level performance; package/controller options have separate SKUs. Select the exact option.
Portable Dust Fume Extractor Ventilation Axial Blower Workshop Fan 16"
SKU unpublished · displayed product code; variation SKU not verified
400mm / 16in720070 dB(A)1200220–240VUnpublishedPortable · industrialvariation SKU unpublished;
Industrial Portable Dust Fume Extractor Ventilation Axial Blower Fan 8" 10" & 12"
EL10033690 · variation
200mm / 8in150061 dB (weighting not stated)180220–240VUnpublishedPortable · industrialNo stock shown in captured variation data.
Industrial Portable Dust Fume Extractor Ventilation Axial Blower Fan 8" 10" & 12"
EL10033612 · variation
250mm / 10in270066 dB (weighting not stated)300220–240VUnpublishedPortable · industrial 
Industrial Portable Dust Fume Extractor Ventilation Axial Blower Fan 8" 10" & 12"
EL10033613 · variation
300mm / 12in390069 dB (weighting not stated)500220–240VUnpublishedPortable · industrial 
New Industrial Extractor Exhaust Axial Blower Ventilation Wall Mounted Plate Fan
EL10033638 · variation
200mm / 8in105060 dB(A), page uses dba65UnpublishedUnpublishedWall · industrialsupply unpublished;
New Industrial Extractor Exhaust Axial Blower Ventilation Wall Mounted Plate Fan
EL10033639 · variation
250mm / 10in185064 dB(A), page uses dba140UnpublishedUnpublishedWall · industrialsupply unpublished; No stock shown in captured variation data.
New Industrial Extractor Exhaust Axial Blower Ventilation Wall Mounted Plate Fan
EL10033640 · variation
300mm / 12in350568 dB(A), page uses dba180UnpublishedUnpublishedWall · industrialsupply unpublished;
New Industrial Extractor Exhaust Axial Blower Ventilation Wall Mounted Plate Fan
EL10033554 · variation
350mm / 14in485072 dB(A), page uses dba175Unpublished285Wall · industrialsupply unpublished;
New Industrial Extractor Exhaust Axial Blower Ventilation Wall Mounted Plate Fan
EL10033641 · variation
400mm / 16in480072 dB(A), page uses dba190UnpublishedUnpublishedWall · industrialsupply unpublished;
New Industrial Extractor Exhaust Axial Blower Ventilation Wall Mounted Plate Fan
EL10033636 · variation
500mm / 20in885075 dB(A), page uses dba370UnpublishedUnpublishedWall · industrialsupply unpublished;
New Industrial Extractor Exhaust Axial Blower Ventilation Wall Mounted Plate Fan
EL10033637 · variation
600mm / 24in1300082 dB(A), page uses dba750UnpublishedUnpublishedWall · industrialsupply unpublished;
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
SKU unpublished · Variation SKU unpublished; not inherited from another option
200mm / 8in444Unpublished25220–240VUnpublishedWall · industrialnoise unpublished; variation SKU unpublished;
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
EL1003132 · variation
250mm / 10in684Unpublished25220–240VUnpublishedWall · industrialnoise unpublished;
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
EL1003133 · variation
300mm / 12in984Unpublished30220–240VUnpublishedWall · industrialnoise unpublished;
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
EL1003266 · variation
350mm / 14in1350Unpublished40220–240VUnpublishedWall · industrialnoise unpublished; No stock shown in captured variation data.
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
EL1003134 · variation
400mm / 16in2880Unpublished80220–240VUnpublishedWall · industrialnoise unpublished;
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
EL1003135 · variation
450mm / 18in5100Unpublished120220–240VUnpublishedWall · industrialnoise unpublished;
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
EL1003267 · variation
500mm / 20in5700Unpublished140220–240VUnpublishedWall · industrialnoise unpublished;
Industrial Metal Extractor Exhaust Ventilation Fan Low Cost 8'', 10'', 12'', 14'', 16'', 18'', 20''
EL1003136 · variation
600mm / 24in7800Unpublished230220–240VUnpublishedWall · industrialnoise unpublished;
Cased Axial Extractor Fan Canopy Kitchen Restaurant Industrial Duct
EL10033485 · displayed product code; variation SKU not verified
350mm / 14in2280Unpublished85220–240VUnpublishedDucted · industrialnoise unpublished;
Industrial Axial Canopy Fan SF Series – High Airflow Ventilation (300mm–500mm)
EL10033800 · variation
300mm / 12in290076 dB (weighting not stated)370Unpublished191Ducted · industrialsupply unpublished;
Industrial Axial Canopy Fan SF Series – High Airflow Ventilation (300mm–500mm)
EL10033801 · variation
400mm / 16in1000078 dB (weighting not stated)1500Unpublished320Ducted · industrialsupply unpublished;
Industrial Axial Canopy Fan SF Series – High Airflow Ventilation (300mm–500mm)
EL10033802 · variation
500mm / 20in1200080 dB (weighting not stated)2200Unpublished396Ducted · industrialsupply unpublished; No stock shown in captured variation data.
Powerful Commercial Axial Metal Canopy Extractor Exhaust Duct Fan 12" 16" 18" 20"
EL10033719 · variation
300mm / 12in3300Unpublished370220–240V210Ducted · industrialnoise unpublished;
Powerful Commercial Axial Metal Canopy Extractor Exhaust Duct Fan 12" 16" 18" 20"
EL10033720 · variation
400mm / 16in5868Unpublished550220–240V149Ducted · industrialnoise unpublished;
Powerful Commercial Axial Metal Canopy Extractor Exhaust Duct Fan 12" 16" 18" 20"
EL10033721 · variation
450mm / 18in12950Unpublished1500220–240V280Ducted · industrialnoise unpublished; Published 216m³/min gives 12,960m³/h; page states 12,950m³/h. Retain hourly value; resolve discrepancy.
Powerful Commercial Axial Metal Canopy Extractor Exhaust Duct Fan 12" 16" 18" 20"
EL10033722 · variation
500mm / 20in9600Unpublished750220–240V290Ducted · industrialnoise unpublished;
High Performance Fume Extractor Fan – 12"/16", 220-240V, Metal Body, 100% Copper Motor
SKU unpublished · displayed product code; variation SKU not verified
300mm / 12in1800Unpublished150220–240V50Ducted · industrialnoise unpublished; variation SKU unpublished;
High Performance Fume Extractor Fan – 12"/16", 220-240V, Metal Body, 100% Copper Motor
SKU unpublished · displayed product code; variation SKU not verified
400mm / 16in4200Unpublished370220–240V50Ducted · industrialnoise unpublished; variation SKU unpublished;
Commercial Cased Axial Extractor Canopy Kitchen Restaurant Industrial Duct Fan
EL10033733 · variation
300mm / 12in2700Unpublished320220–240VUnpublishedDucted · industrialnoise unpublished; No stock shown in captured variation data.
Commercial Cased Axial Extractor Canopy Kitchen Restaurant Industrial Duct Fan
EL10033734 · variation
400mm / 16in4300Unpublished290220–240VUnpublishedDucted · industrialnoise unpublished;
Commercial Cased Axial Extractor Canopy Kitchen Restaurant Industrial Duct Fan
EL10033735 · variation
450mm / 18in6100Unpublished450220–240VUnpublishedDucted · industrialnoise unpublished;
Commercial Cased Axial Extractor Canopy Kitchen Restaurant Industrial Duct Fan
EL10033736 · variation
500mm / 20in6600Unpublished480220–240VUnpublishedDucted · industrialnoise unpublished;
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG10033702 · variation
200mm / 8in150061 dB(A)180220–240VUnpublishedPortable · industrial 
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG10033701 · variation
250mm / 10in270066 dB(A)300220–240VUnpublishedPortable · industrial 
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG10033700 · variation
300mm / 12in390069 dB(A)500220–240VUnpublishedPortable · industrial 
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG1003262 · variation
350mm / 14in492076 dB(A)750220–240VUnpublishedPortable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. No stock shown in captured variation data.
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG10033821 · variation
400mm / 16in720070 dB(A)1200220–240VUnpublishedPortable · industrial 
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG1002364 · variation
450mm / 18in960070 dB(A)1800220–240V950Portable · industrial 
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG1003253 · variation
500mm / 20in780070 dB(A)550220–240VUnpublishedPortable · industrial 
Industrial Portable Ventilation Axial Fume Extractor Fan High Velocity with Flexible PVC Air Duct
ELG1003254 · variation
600mm / 24in1260075 dB(A)750220–240VUnpublishedPortable · industrial 
Portable Ventilation Fan Axial Blower with flexible Duct
ELG10033732 · variation
250mm / 10in270066 dB(A)300110V370Portable · industrialSimilar 110V listings publish different power/noise/pressure; never merge across product pages.
Portable Ventilation Fan Axial Blower with flexible Duct
ELG10033482 · variation
300mm / 12in390071 dB(A)520110V370Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages.
Portable Ventilation Fan Axial Blower with flexible Duct
ELG10033483 · variation
400mm / 16in678080 dB(A)2000110V826Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. No stock shown in captured variation data.
Portable Ventilation Fan Axial Blower with flexible Duct
EL10033605 · variation
600mm / 24in1080092 dB(A)1500110V1100Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. No stock shown in captured variation data.
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL10033690 · variation
200mm / 8in150061 dB(A)180220–240VUnpublishedPortable · industrial 
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL10033612 · variation
250mm / 10in270066 dB(A)300220–240VUnpublishedPortable · industrial 
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL10033613 · variation
300mm / 12in390069 dB(A)500220–240VUnpublishedPortable · industrial 
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL1003248 · variation
350mm / 14in492076 dB(A)750220–240VUnpublishedPortable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. No stock shown in captured variation data.
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL10033821 · variation
400mm / 16in720070 dB(A)1200220–240VUnpublishedPortable · industrial 
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL10033725 · variation
450mm / 18in960070 dB(A)1800220–240V950Portable · industrial 
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL1003249 · variation
500mm / 20in780070 dB(A)550220–240VUnpublishedPortable · industrial 
Portable fan Ventilator Axial Blower Workshop Extractor Fan
EL1003250 · variation
600mm / 24in1260075 dB(A)750220–240VUnpublishedPortable · industrial 
Industrial Portable Ventilation Fan
EL10033732 · variation
250mm / 10in270066 dB(A)300110V370Portable · industrialSimilar 110V listings publish different power/noise/pressure; never merge across product pages.
Industrial Portable Ventilation Fan
EL10033731 · variation
300mm / 12in390071 dB(A)520110V370Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages.
Industrial Portable Ventilation Fan
EL10033723 · variation
400mm / 16in678080 dB(A)2000110V826Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. No stock shown in captured variation data.
Industrial Portable Ventilation Fan
EL10033596 · variation
600mm / 24in1080092 dB(A)1500110V1100Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. No stock shown in captured variation data.
New Portable Ventilator Axial Blower Workshop Extractor Fan
EL10033612 · variation
250mm / 10in270066 dB(A)300220–240VUnpublishedPortable · industrial 
New Portable Ventilator Axial Blower Workshop Extractor Fan
EL10033613 · variation
300mm / 12in390069 dB(A)500220–240VUnpublishedPortable · industrial 
New Portable Ventilator Axial Blower Workshop Extractor Fan
EL10033821 · variation
400mm / 16in720070 dB(A)1200220–240VUnpublishedPortable · industrial 
Portable Ventilator Axial Blower Ventilation Extractor Industrial Fan
EL1003143 · variation
400mm / 16in8520Unpublished1100220–240V380Portable · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Portable Ventilator Axial Blower Ventilation Extractor Industrial Fan
ELG10033642 · variation
400mm / 16in8520Unpublished1100220–240V380Portable · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Portable Ventilator Axial Blower Ventilation Extractor Industrial Fan
EL10033642 · variation
400mm / 16in8520Unpublished1100220–240V380Portable · industrialnoise unpublished; Size-level performance; package/controller options have separate SKUs. Select the exact option.
Powerstar 400mm /16" Industrial Portable Ventilatio Axial Blower Extractor Fan 6780m³/hr - 2000W
EL10033479 · variation
400mm / 16in6780Unpublished2000110VUnpublishedPortable · industrialnoise unpublished; No stock shown in captured variation data.
Portable Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan 110v
EL10033732 · variation
250mm / 10in270066 dB(A)300110VUnpublishedPortable · industrialSimilar 110V listings publish different power/noise/pressure; never merge across product pages. Size-level performance; package/controller options have separate SKUs. Select the exact option.
Portable Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan 110v
ELG10033732 · variation
250mm / 10in270066 dB(A)300110VUnpublishedPortable · industrialSimilar 110V listings publish different power/noise/pressure; never merge across product pages. Size-level performance; package/controller options have separate SKUs. Select the exact option.
Portable Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan 110v
EL10033731 · variation
300mm / 12in390069 dB(A)500110V385Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. Size-level performance; package/controller options have separate SKUs. Select the exact option.
Portable Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan 110v
ELG10033482 · variation
300mm / 12in390069 dB(A)500110V385Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. Size-level performance; package/controller options have separate SKUs. Select the exact option.
Portable Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan 110v
EL10033592 · variation
400mm / 16in678068 dB(A)2000110V326Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. Size-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Portable Powerstar Movable Dust Fume Extractor Ventilation Axial Blower Workshop Fan 110v
EL10033594 · variation
400mm / 16in678068 dB(A)2000110V326Portable · industrialAirflow converted from stated m³/min × 60; this is a unit conversion, not an estimated rating. Similar 110V listings publish different power/noise/pressure; never merge across product pages. Size-level performance; package/controller options have separate SKUs. Select the exact option. No stock shown in captured variation data.
Portable Ventilator Axial Blower Workshop Extractor Fan with 5 meter Air Duct Hose
ELG10033631 · variation
300mm / 12inUnpublished68 dB(A)Unpublished220–240V25–350Wall · industrialairflow unpublished; power unpublished; Airflow printed as 1500–37200m³/h; apparent error not corrected. Excluded pending confirmation.
Portable Ventilator Axial Blower Workshop Extractor Fan with Speed Controller
EL10033631 · displayed product code; variation SKU not verified
300mm / 12in372068 dB(A)Unpublished220–240V25–350Portable · industrialpower unpublished; Published adjustable range 1500–3720m³/h; 3720 is maximum. Sold-out family; not shortlisted.
12-Inch Pneumatic Centrifugal Blower – Industrial-Grade Portable Air Ventilation Fan
EL10033793 · variation
12inUnpublishedUnpublishedUnpublishedUnpublishedUnpublishedPortable · industrialairflow unpublished; noise unpublished; power unpublished; supply unpublished; Compressed-air powered pneumatic blower; numerical airflow and sound not published in readable description. No stock shown in captured variation data.
CF-3 Industrial Centrifugal Fan Blower, 1.1kW Heavy-Duty Metal Housing, Industrial Air Ventilation
SKU unpublished · displayed product code; variation SKU not verified
See drawing320068 dB(A)1100220–240V600–680Ducted · industrialvariation SKU unpublished; CF-3 airflow range 2035–3200m³/h. No paired duty curve; maximum is not a guarantee at required pressure. Drawing diameters Ø1=210mm, Ø2=310mm, not nominal fan size.
10L Portable Air Cooler Fan – Quiet, Energy-Efficient, and Easy to Move | 220V Evaporative Cooling
SKU unpublished · displayed product code; variation SKU not verified
See drawingUnpublished55 dB upper limit65220VUnpublishedPortable · coolingairflow unpublished; variation SKU unpublished; Evaporative cooler; not an extractor.
Powerstar Powerful Barrel Drum Fan for Industrial / Commercial Use 24" 30" & 36" Inches
EL1003314 · variation
24in8357.43Unpublished180220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Airflow converted from 4919 CFM × 1.6990108; not outdoor air exchange. No stock shown in captured variation data.
Powerstar Powerful Barrel Drum Fan for Industrial / Commercial Use 24" 30" & 36" Inches
EL1003313a · variation
30in11128.52Unpublished240220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Airflow converted from 6550 CFM × 1.6990108; not outdoor air exchange.
Powerstar Powerful Barrel Drum Fan for Industrial / Commercial Use 24" 30" & 36" Inches
EL1003315 · variation
36in15313.18Unpublished360220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Airflow converted from 9013 CFM × 1.6990108; not outdoor air exchange.
Commercial Portable High Velocity Floor Electric Chrome Fan 3 Speed Metal 16" 18" 20" 24"
EL1003351 · variation
16inUnpublishedUnpublishedUnpublished220–240VUnpublishedPortable · coolingairflow unpublished; noise unpublished; power unpublished; Circulation only; flow and watts unpublished in readable description. No stock shown in captured variation data.
Commercial Portable High Velocity Floor Electric Chrome Fan 3 Speed Metal 16" 18" 20" 24"
EL1003317 · variation
18inUnpublishedUnpublishedUnpublished220–240VUnpublishedPortable · coolingairflow unpublished; noise unpublished; power unpublished; Circulation only; flow and watts unpublished in readable description.
Commercial Portable High Velocity Floor Electric Chrome Fan 3 Speed Metal 16" 18" 20" 24"
EL1003316 · variation
20inUnpublishedUnpublishedUnpublished220–240VUnpublishedPortable · coolingairflow unpublished; noise unpublished; power unpublished; Circulation only; flow and watts unpublished in readable description.
Commercial Portable High Velocity Floor Electric Chrome Fan 3 Speed Metal 16" 18" 20" 24"
EL10033441- · variation
24inUnpublishedUnpublishedUnpublished220–240VUnpublishedPortable · coolingairflow unpublished; noise unpublished; power unpublished; Circulation only; flow and watts unpublished in readable description.
18'' Commercial Portable Velocity Chrome Tilting Floor Electric Fan 3 Speed Metal
EL1003317 · displayed product code; variation SKU not verified
18in3652.87Unpublished120220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Converted from published 2150CFM; shared rating retained without assumption about performance.
20" Chrome Commercial Portable High Velocity Floor Electric Fan 3 Speed Metal
EL1003316 · displayed product code; variation SKU not verified
20in3652.87Unpublished120220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Converted from published 2150CFM; shared rating retained without assumption about performance.
16'' Chrome Commercial Portable High Velocity Floor Electric Fan 3 Speed Metal
EL1003351 · displayed product code; variation SKU not verified
16in3652.87Unpublished120220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Converted from published 2150CFM; shared rating retained without assumption about performance.
Portable High Velocity Floor Electric Chrome
EL1003316 · displayed product code; variation SKU not verified
20inUnpublishedUnpublishedUnpublished220–240VUnpublishedPortable · coolingairflow unpublished; noise unpublished; power unpublished; Circulation only; flow and power unpublished.
Industrial Portable Cooling Drum / Barrel Fan with Wheels High Velocity Air Circulation Fan
EL1003363 · variation
500mm / 20in7000Unpublished200220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Published flow ranges 6500–7000 / 7500–7900 / 8500–9000m³/h respectively; upper value shown. No stock shown in captured variation data.
Industrial Portable Cooling Drum / Barrel Fan with Wheels High Velocity Air Circulation Fan
EL1003372 · variation
600mm / 24in7900Unpublished350220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Published flow ranges 6500–7000 / 7500–7900 / 8500–9000m³/h respectively; upper value shown.
Industrial Portable Cooling Drum / Barrel Fan with Wheels High Velocity Air Circulation Fan
EL1003365 · variation
700mm / 28in9000Unpublished610220–240VUnpublishedPortable · coolingnoise unpublished; Circulation only. Published flow ranges 6500–7000 / 7500–7900 / 8500–9000m³/h respectively; upper value shown.

Common Mistakes When Choosing an Extractor Fan

Avoid selecting by diameter alone, mixing litres per second with m³/h, or treating a maximum flow as an installed guarantee. Check each variation rather than copying specifications from another model. Identify the replacement-air path before increasing extraction.

Other common errors include fitting a general fan to a hazardous process, treating a cooling fan as an extractor, overlooking the voltage supply and comparing noise figures measured under different conditions. A 110V model requires the correct supply; a product's plug or cable does not establish its suitability for a wet location.

Plan safe maintenance access, cleaning and replacement of worn parts. Keep product instructions with the installation records. Review performance if the room use, ductwork, filters or occupancy changes.

Frequently Asked Questions

Is a bigger extractor fan always better?

No. The useful choice delivers the design airflow at the system pressure with suitable noise, controls and environmental protection. Excess capacity can cause avoidable noise and draughts.

Can I size a fan from floor area alone?

You need height for a volume/ACH calculation. For domestic ventilation, also check the applicable room extract and whole dwelling provisions rather than relying only on volume.

Is a 100mm fan enough for every bathroom?

No. Check that specific model's installed flow, duct run, electrical rating and controls. Diameter is only one part of the decision.

Can the calculator guarantee a product is suitable?

It provides a preliminary shortlist from published data. Final selection depends on the installation and manufacturer information. When information is missing, the result explains what needs checking.

What if no product matches?

Contact Powerstar with the airflow target, application, dimensions and proposed route. Do not choose an unsuitable fan just to obtain a result. A specialist design or another fan type may be required.

Do all industrial fans remove hazardous fumes?

No. A product title mentioning fumes does not establish a complete exposure-control solution, explosion protection or suitability for a particular substance. Use competent advice for hazardous processes. [3]

Shop Extractor Fans at Powerstar Electricals

Explore industrial extractor fans, portable ventilation fans, bathroom fans, canopy fans and duct hose.

For help shortlisting, send Powerstar your room dimensions, activity, required airflow, duct diameter and route, electrical supply and noise priorities. Ask for any missing sound, moisture or pressure-performance data before ordering. Contact the team with your project details.

## Sources and verification

[1] England: Approved Document F, Volume 1, 2021 edition — see Table 1.1 and system-specific provisions.

[2] HSE: Assessing the risk of poor ventilation.

[3] HSE HSG258: Controlling airborne contaminants at work, including fan selection and the design duty point.

[4] HSE CAIS10: Ventilation in catering kitchens.

[5] England: Approved Document F, 2026 edition and Circular 01/2026 for commencement and transition.

[6] Wales: Approved Document F.

[7] Scotland: Building standards technical handbooks.

[8] Northern Ireland: Technical Booklet K.

Product information is from the linked Powerstar Electricals listings, checked on 3 November 2026. Published ratings have not been independently laboratory tested. Availability and specifications can change; confirm the exact variation before ordering.